HVRF Indoor Units

Hybrid VRF (HVRF) indoor units are designed to connect with a Hydro Branch Controller (HBC) in a HVRF System. HVRF indoor units connect to the HBC using water a medium of heat exchange instead of refrigerant. Current line-up of indoor units includes low and medium static ducted, 4-way air flow ceiling cassette and floor console models.

Need help choosing?

Find the best solution for your needs with our Product Selector

PLFY-WL-VEM-E

HVRF Indoor Units

PLFY-WL-VEM-E

PLFY-WL20-125VEM-E

  • Capacity Range: 2.2 – 14 kW
  • Optimum airflow
  • High and low-ceiling modes
  • Automatic fan speed
  • 3D i-See Sensor
  • Optional flow control valve (external)
Read More
PLFY-WL-VFM-E

HVRF Indoor Units

PLFY-WL-VFM-E

PLFY-WL10-40VFM-E

  • Capacity Range: 1.2 – 4.5 kW
  • Compact and light-weight design – only 245 mm high
  • Horizontal airflow
  • 3D i-See Sensor
  • Optional flow control valve (external)
Read More
PEFY-WP-VMS1-E

HVRF Indoor Units

PEFY-WP-VMS1-E

PEFY-WP10-50VMS1-E

  • Capacity Range: 1.2 – 5.6 kW
  • Compact design with 200 mm height
  • Low noise design
  • External Static Pressure 5-50 Pa
  • Built-in drain pump option
Read More
PEFY-W-VMS-A

HVRF Indoor Units

PEFY-W-VMS-A

PEFY-W10-50VMS-A

  • Capacity Range: 1.2 – 5.6 kW
  • Compact design with 200 mm height
  • Low noise design
  • External Static Pressure 5-50 Pa
  • Built-in drain pump option
  • Built-in flow control valve
Read More
PEFY-WP-VMA-E

HVRF Indoor Units

PEFY-WP-VMA-E

PEFY-WP20-125VMA-E

  • Capacity Range: 2.2 – 14 kW
  • Compact design
  • External static pressure up to 150 Pa
  • Re-configurable return air inlet
  • Built-in drain pump option
Read More
PEFY-W-VMA(L)-A

HVRF Indoor Units

PEFY-W-VMA(L)-A

PEFY-W20-125VMA(L)-A

  • Capacity Range: 2.2 – 14 kW
  • Compact design
  • External static pressure up to 150 Pa
  • Re-configurable return air inlet
  • Built-in drain pump option
  • Built-in flow control valve
Read More
PEFY-W-VMA2-A

HVRF Indoor Units

PEFY-W-VMA2-A

PEFY-W20-125VMA2-A

  • Capacity Range: 2.2 – 14 kW
  • Compact design
  • External static pressure up to 150 Pa
  • Re-configurable return air inlet
  • Built-in drain pump option
  • Built-in flow control valve
Read More
PEFY-WL-VMHS-A

HVRF Indoor Units

PEFY-WL-VMHS-A

PEFY-WL40-125VMHS-A

  • Capacity Range: 4.5 – 14 kW
  • Flexible duct design
  • Drain pump (option)
  • DC fan motor
  • Four external static pressure settings
  • Three fan speeds settings
  • Optional flow control valve (external)
Read More

Why Choose a City Multi Hybrid VRF System?

City Multi Hybrid VRF indoor units connect to the Hybrid Branch Controller (HBC) using water as the heat transfer medium, eliminating refrigerant from occupied spaces. Our comprehensive range, from ceiling cassettes and ducted systems to wall-mounted and floor console models, delivers flexible solutions for offices, hotels, retail, healthcare facilities, and heritage buildings. Some of the benefits of Hybrid City Multi VRF air conditioning include:

Industry-Leading 2-Pipe Hybrid VRF Technology

Mitsubishi Electric City Multi Hybrid VRF is an industry-first technology that revolutionises VRF systems by combining the benefits of both VRF and chilled water systems. This innovative approach transfers the refrigerant between the outdoor unit, the HBC, and water for indoor distribution. This creates a unique two-pipe hybrid system that sets new standards for comfort, safety, and efficiency in building climate control.

Enhanced Safety Through Advanced Design

The system’s distinctive design eliminates refrigerant from occupied spaces by using water between the HBC and indoor units, ensuring full compliance with AS/NZS 5149 standards. Removing the need for refrigerant leak detection systems makes it particularly suitable for sensitive applications such as healthcare facilities, schools, and hotels, where occupant safety and regulatory compliance are critical.

Efficient Operation with Superior Comfort

Available in both air-cooled and water-cooled configurations, with R410A or R32 refrigerant options, the system delivers exceptional energy efficiency through heat recovery during simultaneous cooling and heating operations. The water-based distribution system provides naturally stable temperatures and milder off-coil temperatures, ensuring consistent comfort across all zones while simplifying installation compared to traditional 4-pipe systems. Comprehensive control options, including centralised building management systems and individual controllers, enable optimised application performance.

Types of HVRF indoor units

Ceiling cassette air conditioners

PLFY-WL-VEM-E 4-Way Air Flow Ceiling Cassette

Ideal for air conditioning rooms with limited wall, floor and ceiling space, this ceiling cassette air conditioner has a capacity range of 2.2 – 14 kW, providing comfort to residential and commercial spaces alike.

Benefits:

With a whisper-quiet operation, it’s ideal for master bedrooms, living rooms, and other single-room residential or commercial uses. This indoor unit is designed for simple, quick, and cost-efficient.

Features:

The PLFY-WL-VEM-E boasts a range of unique features that ensure comfort and convenience. Some include:

  • 72 different airflow patterns: It has individually adjustable vane angles, which are configurable for 4, 3, or 2-way throws.
  • High and low-ceiling modes: These modes adjust airflow volume to match room height, while horizontal airflow reduces cold drafts.
  • The optional 3D i-See Sensor: Monitors occupant position, body temperature and floor temperature to enable energy-saving operation based on room occupancy.

PLFY-WL VFM-E 4-Way Ceiling Cassette

With compact dimensions of 600 mm x 600 mm and a slim profile of 245 mm in height, the PLFY-WL VFM-E series is designed to fit seamlessly into 2 x 2 ceiling construction specifications. Maintaining a compact size, this HVRF air conditioning indoor unit has a capacity range of 1.2 – 4.5 kW, providing options for commercial spaces, including office and restaurant environments.

Benefits:

Thanks to its design, the PLFY-WL VFM-E ensures flexible, cost-efficient and easy installation even in narrow ceiling spaces. Equipped with the latest cooling and heating technologies, you can customise the airflow of this ceiling cassette air conditioner to enhance comfort and minimise cold drafts.

Features:

Some of the PLFY-WL VFM-E’s features include:

  • Horizontal airflow capability: This directs air supply horizontally into the room, minimising the feeling of a cold draft.
  • An optional external flow control valve: It can enable more accurate power apportioning via the AE-200E central controller, ideal for projects requiring individual billing.
  • An optional 3D i-See Sensor: The sensor provides advanced occupancy detection, monitoring people’s location, number, and body temperature in the room to optimise power consumption and maintain comfort. It offers direct and indirect airflow settings for improved air distribution tailored to room occupancy.

 

Ceiling concealed or ducted air conditioners

PEFY-WP VMS1-E Low Static Pressure Ceiling Concealed

Perfect for hotels and spaces requiring discreet air conditioning solutions, this low static pressure ceiling concealed unit combines a slim design with quiet operation. Available in capacities up to 5.6 kW.

Benefits:

With a centrifugal fan and coil design, the unit has an ultra-quiet operation, ranging from 22 dB with low airflow to 35 dB at low speed. Its compact profile, with a height of 200 mm, makes it easy to install in a ceiling with limited space, a bulkhead, or a small cavity.

Features:

This ceiling concealed low static unit is ideal for many commercial spaces, thanks to the following features:

  • Selectable 50 Pa external static pressure: External static pressure can be adjusted to 5, 15, 35 or a maximum of 50 Pa to accommodate various ductwork configurations. Units are factory-set to 15 Pa as standard.
  • Refrigerant/drain piping and a control box: Available on either the right or left side, it enables flexible installation options.
  • Optional card key integration: Ideal for hotel rooms, offices, and other commercial spaces, this feature prevents wasteful operation by automatically shutting the unit off when guests leave their rooms.

PEFY-W VMS-A Low Static Pressure Ceiling Concealed

The slim 200 mm height profile is consistent across all models (from 1.2 – 5.6 kW capacities), enabling easy installation in tight ceiling spaces or bulkheads. It is suitable for an array of spaces, such as offices, hotel rooms and bedrooms.

Benefits:

Carefully designed for comfort and convenience, this ducted air conditioner is ideal for areas where ultra-quiet operation and minimal ceiling space are priorities. The unit operates at a noise level as low as 22dB at a low fan speed.

Features:

The PEFY-W VMS-A includes the following features:

  • An external static pressure: This can be adjusted to 5, 15 (factory default), 35, or 50 Pa.
  • An optional drain pump: By eliminating the need for a drain trap it achieves a maximum lifting height of 550 mm. (This accessory is sold separately.)
  • Built-in flow control valve: A charge calculation function that can be performed by AE-200E central controller for individual billing.

PEFY-WP-VMA-E Medium Static Pressure Ceiling Concealed

Medium static pressure ceiling concealed units are designed for applications requiring greater external static pressure and flexible installation options. They are available in two variants: models with built-in drain pumps (VMA-E) and models without drain pumps (VMAL-E) for greater piping layout flexibility.

Benefits:

The consistent 250mm height profile across all models (capacities ranging from 2.2 – 14 kW) allows for installation in restricted ceiling spaces, providing options for residential and commercial buildings where maximising space is important.

Features:

This ducted air conditioner includes the following features:

  • Five selectable external static pressure settings: Ranging up to 150 Pa, the unit has extensive duct design and air outlet configuration flexibility.
  • Built-in drain pump: This allows for more freedom in piping layout design.
  • A re-configurable return air inlet: If a bottom inlet is required, the unit’s panel and air filter locations can be switched, allowing for installation in tight spaces.

PEFY-W-VMA(L)-A Medium Static Pressure Ceiling Concealed (High-Efficiency Model)

High-efficiency medium static pressure ceiling-concealed units are designed for applications requiring greater external static pressure and adaptable installation. They are available in two variants:

  • VMA-A models: Equipped with a built-in drain pump for efficient condensate removal.
  • VMAL-A models: Designed without a drain pump, offering greater flexibility in piping layout configurations.

Benefits:

The consistent 250mm height profile across all models (capacities ranging from 2.2 – 14 kW) allows for easy and cost-effective installation in commercial and residential areas with restricted ceiling spaces.

Features:

The PEFY-W-VMA(L)-A features:

  • A built-in flow control valve: This enables individual billing through the AE-200E central controller’s charge calculation function.
  • Five selectable external static pressure settings: Selectable up to 150 Pa, it provides flexible duct design and air outlet configuration.
  • Built-in drain pump options: This consists of two variants, which allows increased flexibility in piping layout design.
  • A re-configurable return air inlet: For units where a bottom inlet is preferred, it can be re-configured to allow installation in tight spaces.

PEFY-W-VMA2-A Medium Static Pressure Ceiling Concealed

The medium static pressure ducted air conditioner is available in two variants. For greater piping layout flexibility, you can select from models with built-in drain pumps (VMA2-A) or models without drain pumps (VMA2L-A).

Benefits:

The units maintain a consistent 250 mm height profile across all models (2.2 – 14 kW capacities), enabling installation in restricted ceiling spaces while providing flexible operation to a space’s unique requirements.

Features:

The PEFY-W-VMA2-A includes the following features:

  • Built-in flow control valve: Designed with AE-200E central controller’s charge calculation function to enable individual billing capability.
  • Five selectable external static pressure settings: Reaching 150 Pa provides extensive duct design and flexibility in air outlet configuration.
  • Re-configurable return air inlet: Flexible panel and air inlet locations allow a bottom air inlet if required, enabling easy installation in tight spaces.
  • Built-in drain pump options: Consisting of two variants, allowing increased freedom with pipe layout design.

PEFY-WL-VMHS-A High Static Pressure Ceiling Concealed

This unit is designed for projects requiring powerful, adaptable ducted air conditioning systems that suit diverse architectural layouts and performance needs.

Benefits:

With an extended capacity range of 4.5 – 14 kW, the PEFY-WL-VMHS-A has a flexible duct design, ensuring it can be customised to suit the varying demands of commercial spaces.  DC fan motors assist in improving energy efficiency compared to AC fan models.

Features:

This high static pressure ducted air conditioner is designed with:

  • An optional drain pump: This offers enhanced lift capacity — up to 550 mm for WL40-125VMH(S) models and up to 700 mm for WL200-250VMHS models — reducing horizontal piping requirements.
  • External static pressure: With 4 settings from 50 to 200 Pa, these units are ideal for complex installations requiring extensive ductwork and customised air distribution.
  • An external flow control valve: This optional accessory can be added for individual billing applications to enable charge calculation functionality through the AE-200E central controller.

Wall mounted air conditioners

PKFY-WL VLM-E Wall Mounted

Designed for residential and small commercial applications, including homes, offices, restaurants, and schools, the wall mounted air conditioner is available in a range of capacities (1.2 – 4.5 kW), suitable for various space sizes, from single rooms to larger open-plan areas.

Benefits:

Seamlessly integrating with City Multi VRF control and monitoring systems while complementing modern interiors, this wall mounted indoor unit is versatile and ideal for spaces where duct installation or ceiling space is limited or unavailable.

Features:

The PKFY-WL VLM-E includes the following features:

  • An optional drain pump: It has up to 800mm lift capacity for a flexible piping layout.
  • 5 vane angle settings: Alongside 4 fan settings, they can provide optimal air distribution and achieve horizontal airflow, reducing cold drafts.
  • An optional control valve (external): The AE-200E central controller enables a charge calculation function for individual billing.
  • Low noise levels: Models WL10/15/20/25 can operate at a noise level as low as 22 dB on low speed.

PKFY-WL-VKM-E Wall Mounted

This high-capacity wall-mounted unit is one of our largest models of this type, with outputs ranging from 5.6 to 9 kW and is designed for larger spaces requiring powerful air conditioning. It is ideal for open-plan areas such as classrooms and restaurants where significant cooling and heating capacity is required.

Benefits:

It features a stylish design that complements modern interiors while seamlessly integrating with City Multi VRF control systems. It is engineered to provide advanced performance and energy efficiency for commercial and institutional applications.

Features:

Some of the features of the wall mounted air conditioner include:

  • An optional drain pump: This addition expands installation possibilities, with drain connections rising as high as 800 mm for diverse building designs.
  • Optional flow control valve: This feature uses the AE-200E central controller for projects requiring individual billing to estimate the power apportioning function accurately.

Floor Console air conditioners

PFFY-W-VCM-A Floor Console – Concealed

This versatile floor console unit is designed for efficient perimeter zone air conditioning. With compact dimensions (200 mm deep, 700 mm wide, 615 mm high) and detachable legs (690mm high), it’s suitable for direct floor mounting or concealed installation behind walls, joinery cupboards, or perimeter bulkheads.

Benefits:

Offering flexible installation options, the design of the PFFY-W-VCM-A allows for unobstructed delivery of efficient air conditioning while maintaining interior design aesthetics.

Features:

The floor console air conditioner includes the following:

  • A built-in flow control valve: Enables individual billing through the AE-200E central controller’s charge calculation function.
  • Maximum external static pressure of 60 Pa: This additional external capacity ensures a flexible duct extension, branching and air outlet configuration.

PFFY-WL-VEM-A Floor Console – Exposed

This versatile floor console unit is designed for effective perimeter zone air conditioning. With a slim 217 mm depth profile and robust construction, it’s suitable for both floor and wall mounting with water pipe connections from either bottom or rear. Available in clear white and pearl grey finishes.

Benefits:

Perfect for heritage listed buildings and applications where ceiling voids are unavailable and wall modifications are not permitted. The design allows water connections and electrical work to run under the floor, preserving architectural integrity while delivering whisper-quiet operation ideal for offices, retail spaces, high-end residential properties, and hospitals.

Features:

The floor console air conditioner includes the following:

  • Three fan speed settings: Provides customisable comfort with operation as quiet as 23 dBA for minimal disturbance.
  • DC fan motor and improved heat exchanger: Optimises system efficiency for reduced power consumption and running costs.
  • Built-in remote controller housing: Convenient control access integrated into the unit chassis for clean aesthetics.
  • Flexible installation options: Floor or wall mounting with bottom or rear water pipe connections to adapt to various building layouts.

 

FREQUENTLY ASKED QUESTIONS

Residential and commercial air conditioners are built to meet the specific needs of their intended spaces. This means they vary in construction since commercial spaces typically require more advanced technologies to suit their larger and more complex floor plans, increased occupancy and control requirements. Some key differences include:

 

  • Capacity: Commercial applications often require higher capacity indoor units than residential systems can provide. City Multi indoor units are available in capacities up to 14 kW to accommodate larger spaces and higher cooling or heating loads..
  • Control: Commercial air conditioning systems are designed for greater control integration with central control systems or a BMS.
  • Components: Key components in commercial air conditioners are designed for longer, more continuous use. Residential air conditioners are designed for home use.

In healthcare facilities where comfort, safety and air quality are priorities, a reliable, efficient air conditioning system is essential. The City Multi Hybrid VRF system eliminates refrigerant from occupied spaces by using water between the HBC and indoor units, ensuring compliance with AS/NZS 5149 standards without requiring leak detection systems.

The water-based secondary circuit provides naturally stable temperatures throughout the year with milder off-coil temperatures, maintaining consistent comfort across different zones.

The selection of heat recovery models allows for operation that reduces energy consumption during simultaneous cooling and heating, compared to heat pump models, helping to lower operational costs for facilities requiring 24/7 climate control.

Learn more about the air solutions for healthcare facilities and how City Multi Hybrid VRF air conditioning will benefit their individual needs.

Yes. HVRF indoor units using heat recovery outdoor units deliver optimal energy efficiency thanks to simultaneous heating and cooling operations. The system reduces power consumption by recovering heat during operation, with energy savings increasing as simultaneous heating and cooling becomes more frequent.

VRF (Variable Refrigerant Flow) air conditioning uses refrigerant throughout the entire system. In VRF systems, refrigerant flows from the outdoor unit through a BC Controller to the indoor units.

HVRF (Hybrid Variable Refrigerant Flow) uses a dual-circuit approach: refrigerant circulates between the outdoor unit and the Hybrid Branch Controller (HBC), while water circulates between the HBC and indoor units. This hybrid design eliminates refrigerant from occupied spaces while maintaining the performance benefits of VRF technology.

Hybrid VRF indoor air conditioners are available from Mitsubishi Electric Diamond Dealers in Australia.  Contact us with your project requirements.