Bert Newton Retirement Village

A premium aged care project using Mitsubishi Electric City Multi two-pipe heat recovery VRF to deliver efficient, independent climate control across apartments, common areas, and care facilities.

Download PDF
Aerial view of the Bert Newton Retirement Village in Highett, Victoria, with Mitsubishi Electric CITY MULTI outdoor units on the roof

About the project

Balancing Comfort, Efficiency and Resident Autonomy

When the Bert Newton Retirement Village opened its doors in Highett, Victoria, the goal was clear: deliver dignified, luxurious living for over 250 residents across a mixed care model — and do so sustainably.

This multi-stage development comprises 209 residential units, including 85 independent living apartments, 45 serviced apartments, and a 79-bed care centre. Alongside these shared amenities, such as a café, bar, pool, and cinema, support the village’s community ethos.

As with many contemporary aged care and retirement projects, the HVAC design needed to balance comfort, efficiency, and independence while navigating tight construction constraints.

Independent living apartment at Bert Newton Retirement Village with a Mitsubishi Electric CITY MULTI high-wall indoor unit above the dining area

The challenge

Comfort Zones

A key challenge was ensuring individual thermal control within apartments while still meeting overall site energy goals. Independent living demands independent control, but managing this at scale — across more than 200 residences — is no small task.

The design also needed to support heat recovery for improved energy efficiency, not just in apartments, but in high-use common spaces such as the cinema, salon, bar, and sitting areas. Additionally, the site required heat pump systems in circulation zones, including common hallways.

Constrained riser space further complicated matters, restricting the refrigerant pipework layout. And finally, accurate power apportioning was required so each apartment could be fairly billed for HVAC use.

The solution

Two Pipes, One Outcome

To meet the performance requirements within spatial limits, a two-pipe heat recovery VRF system was installed. This approach reduced the piping required to fit within the limited pipe risers. The VRF system enabled simultaneous heating and cooling across most of the site.

High-wall mounted indoor units were selected for master bedrooms and living spaces, offering intuitive, localised control for each resident. These units delivered efficient performance and tenant autonomy, both of which are essential in a residential aged care environment.

Using Mitsubishi Electric multi-port branch controllers, made possible by the two-pipe configuration, meant just three manholes were required per floor instead of 15 from an alternative brand’s branch controllers, significantly reducing associated building costs.

The hallway spaces were serviced by heat pump systems, ensuring that circulation areas remained at required temperatures.

Smart Power, Seamless Exit

The project also addressed a common issue in multi-dwelling HVAC design: fault triggering when individual tenants switch off their systems. In other systems, this risk is typically managed by installing additional “multi-tenant cards” to prevent the system from registering a fault when one unit powers down.

The City Multi VRF system from Mitsubishi Electric offered a distinct advantage. The systems are designed to remain stable even when tenants turn off their own units. This design feature removed the need for additional hardware and streamlined the installation process.

“That design saved us a lot of hassle,” says Michael Eade, Director, Contract Air Conditioning. “Other systems often need multi-tenant cards to stop faults when someone switches off their unit. With City Multi, that problem simply didn’t exist, and it gave us one less thing to worry about during commissioning.”

Electrical metering was also carefully planned. Indoor units drew from each apartment’s own power, while central outdoor units were CT metered to apportion shared energy use back to individual residences, enabling accurate tenant billing.

Rows of Mitsubishi Electric CITY MULTI PURY heat recovery outdoor units on the Bert Newton Retirement Village roof
Left: Robert Baker, Project Manager, Contract Air Conditioning Pty. Ltd. Right: City Multi 2-Pipe heat recovery units. Images courtesy Australian National Construction Review – Photographer Joe Sabljak

The outcome

The Mitsubishi Electric City Multi Heat Recovery VRF system is well suited to applications such as nursing homes, where simultaneous heating and cooling is required.

“The design and features of the Mitsubishi Electric City Multi heat recovery VRF were like it was purpose-built for this project,” says Michael Eade. “Eliminating the need for additional apartment cards, using a two-pipe (heat recovery) system to reduce piping and installation costs, accommodating limited pipe risers, and minimising the number of branch boxes required, all contributed to a system that is simpler to install and maintain.”

“The Mitsubishi Electric commissioning team’s knowledge got us over the line, too. We worked together on a staggered commissioning approach that meant residents could move in seamlessly as each stage was completed. Their service support has been excellent when problems arise, though they’ve been minimal,” mentioned Michael.

For large-scale developments like the Bert Newton Retirement Village, the two-pipe heat recovery VRF system from Mitsubishi Electric offers a streamlined solution that meets project goals while delivering meaningful cost savings.

Unit Information

Heat Recovery

Air Cooled Heat Recovery

  • Capacity range: 22 to 124 kW
  • 2-pipe heat recovery for simultaneous heating and cooling
  • Reduced condenser footprint
  • External static pressure up to 80 Pa
  • Max. height difference up to 90 m
  • Cooling operation up to 52°C ambient
Read more

Heat Pump

Air Cooled Heat Pump

  • Capacity range: 22 to 150 kW
  • Reduced condenser footprint
  • External static pressure up to 80 Pa
  • Max. height difference up to 90 m
  • Advanced “Low Noise” function
Read more

Heat Pump

PUMY-SP Series

  • Capacity Range: 9.0 kW - 15.5 kW
  • Compact Outdoor Unit
  • Quiet Operation
  • Diverse indoor unit lineup
  • Energy-Efficient Inverter
Read more

City Multi VRF Air Conditioning Systems

City Multi - BC Controller

  • 2-pipe heat recovery for simultaneous heating and cooling
  • Single BC controller for systems up to 40 kW
  • Main BC controller for 40, 101 or 124 kW outdoor units
  • Connects up to 11 sub-BC controllers
  • Up to 90 m piping from BC controller to indoor units
  • Line branching reduces refrigerant use
Read more

Ceiling Concealed

PEFY-P-VMA(L)-E4

  • Capacity Range: 2.2 – 16 kW
  • Compact design
  • External static pressure up to 150 Pa
  • Re-configurable return air inlet
  • Built-in drain pump option
Read more

Ceiling Concealed

PEFY-P-VMX(L)-E(1)

  • Capacity Range: 1.7 – 7.1 kW
  • Compact design
  • 450 mm deep
  • Three return air intake positions
  • External static pressure up to 45 Pa
  • Built-in drain pump option
Read more

Wall Mounted

PKFY-P-VKM-E

  • Capacity Range: 7.1 & 11.2 kW
  • Optional drain pump
  • Complements any decor
Read more

Wall Mounted

PKFY-P-VLM-E

  • Capacity Range: 1.2 – 5.6 kW
  • Optional drain pump
  • Airflow control
  • Complements any decor
  • Reduced noise levels
Read more

Ceiling Cassette

PLFY-P-VEM-E

  • Capacity Range: 3.6 – 16 kW
  • Optimum airflow
  • High and low-ceiling modes
  • Automatic fan speed
  • Easy installation
  • Easy cleaning
Read more

Ceiling Cassette

PLFY-P-VFM-E

  • Capacity Range: 1.7 – 5.6 kW
  • Compact and light-weight design – only 245 mm high
  • Horizontal airflow
  • 3D i-See Sensor
Read more

Centralised Air Conditioning Controllers

AE-200E

  • 10.4 inch colour LCD touch screen with backlit display
  • Weekly scheduling by group, with night setback
  • Control and monitor building air conditioning remotely through a web browser on a PC, tablet or smartphone
  • Control and monitor up to 50 indoor units, or up to 200 with three AE-50E / EW-50E expansion controllers
  • Energy monitoring*1 with graphs by unit, group and block, compared against targets and the previous year
  • Historical trend analysis and downloadable CSV energy data*1
Read more

Air Conditioning Wall Controllers

PAR-41MAA Standard Wired Wall Mounted Controller

  • Backlit LCD screen with inverted colour display
  • Works with M Series*, Mr Slim and City Multi indoor units
  • Weekly timer, up to 8 patterns per day
  • Night setback
  • Energy saving operation schedule
  • Temperature range restriction
Read more