Next Hotel Brisbane

Renovated hotel upgrades air conditioning system to Mitsubishi Electric 2-pipe heat recovery water cooled CITY MULTI VRF utilising existing chilled water system.

Download PDF

The challenge

One of Brisbane’s oldest hotels, the Lennon’s Hotel located in Brisbane Queen St Mall underwent a major make-over in 2014 and was relaunched as the new 30 storey Next Hotel Brisbane. The previous set-up of the building consisted of hotel rooms on the lower level with the remaining upper levels used as office space.

With the new Next Hotel using all 30 levels for hotel rooms the existing chilled water system would have to be completely revamped to suit a hotel application. Modifying the existing chilled water system would put the project over budget so an alternative solution was required.

An additional requirement from the client was to allow hotel guests to control everything in their rooms via smart phone.

The solution

The solution to this was Mitsubishi Electric’s Water Cooled CITYMULTI VRF technology which utilises water as the heat rejection source as opposed to conventional air cooled systems.

Utilising the existing water circuit from the previous chiller system and with the additional feature of the Water Cooled VRF condensing units having no heat rejection (no need for additional cooling in plant space), the condensing units were installed in small plant rooms which took up minimal floor space thus providing more usable floor space for the hotel.

In addition to the Water Cooled condensing units, Mitsubishi Electric’s 2-pipe heat recovery systems were used which provide simultaneous heating and cooling when required providing year round comfort to the hotel guests.

To allow the Mitsubishi Electric VRF systems to work with the smart devices in the hotel rooms a BACnet BMS adapter was provided which was then programmed by Mitsubishi Electric control engineers with the BMS Company. Mitsubishi Electric AG-150 central controllers were installed in the MSB which allowed for central monitoring for faults.

Unit Information

Heat Recovery

Water Cooled Heat Recovery

  • Capacity range: 22 to 150 kW
  • Double heat recovery, in both the refrigerant and water circuits
  • 2-pipe heat recovery for simultaneous heating and cooling
  • Reduced plant room sizes
  • Re-uses existing building water circuits
  • Connects 15 to 50 indoor units per condensing unit
Read more

Wall Mounted

PKFY-P-VKM-E

  • Capacity Range: 7.1 & 11.2 kW
  • Optional drain pump
  • Complements any decor
Read more

Ceiling Concealed

PEFY-P-VMHS-E

  • Capacity Range: 4.5 – 16 kW
  • Flexible duct design
  • Drain pump (option)
  • DC fan motor
  • External Static Pressure 50-250 Pa
  • Three fan speeds settings
Read more

City Multi VRF Air Conditioning Systems

City Multi - BC Controller

  • 2-pipe heat recovery for simultaneous heating and cooling
  • Single BC controller for systems up to 40 kW
  • Main BC controller for 40, 101 or 124 kW outdoor units
  • Connects up to 11 sub-BC controllers
  • Up to 90 m piping from BC controller to indoor units
  • Line branching reduces refrigerant use
Read more