Lossnay Ventilation

LGH-RVX3-E Lossnay ventilators

LGH-15-200RVX3-E

  • Air flowrate 42 L/s (model 15) to 556 L/s (model 200)
  • Indoor air quality
  • Energy efficient heat recovery ventilation
  • Simultaneous air supply and exhaust stale air
  • CO2 sensor
  • Use with Mr Slim and City Multi systems
  • Fresh air without windows open
  • Advanced control system
  • High efficiency air filter

The Lossnay LGH-RVX3-E Mechanical Ventilation Heat Recovery (MVHR) systems are designed to supply clean, fresh air into any commercial building while simultaneously extracting stale air, ensuring good indoor air quality for occupant wellbeing. These units can also recover valuable heat and latent energy from inside the building, maximising energy efficiency and reducing running costs.

Available in: 15, 25, 35, 50, 65, 80, 100, 160, 200

Simultaneous air supply and exhaust_LGH

Simultaneous air supply and exhaust

Lossnay is the ultimate home ventilation system that provides fresh clean air from outside, while removing both moisture and stale indoor air at the same time. Bringing fresh air into the house can help improve indoor air quality by removing indoor pollutants including CO2, ozone, VOC’s, etc.

Heat recovery ventilation_LGH

Heat recovery ventilation

Heat is recovered from the outgoing stale air. This heat is utilised to pre-heat incoming fresh air so your air conditioning system is not required to work as hard to maintain desired room temperature.

Use with Mr Slim & City Multi Systems

Use with Mr Slim & City Multi Systems

Lossnay can be integrated with a Mitsubishi Electric Mr. Slim and City Multi air conditioning systems. The ducted system provides heating and cooling while the Lossnay ventilator brings in fresh air into the home while expelling the stale air at the same time.

The heat recovery ventilators to help to reduce the load on the ducted air conditioning system.

Vertical Installation

Vertical Installation

The RVX3 can be fitted vertically using optional parts, providing more options for the choice of installation location. Follow the specific instructions in the Installation Manual for vertical installation of the RVX3 series.

Standard G4 Filter (Supplied)

Standard G4 Filter (Supplied)

The improved standard filter cuts pollen and dust for fresh, clean air. They can be washed for easy maintenance. Replacement filter is available as optional part no. PZ-**RF3-E. (Coarse 60% (ISO 16890: 2016).

Advanced high efficiency filters (Optional)

Advanced high efficiency filters (Optional)

The supply and exhaust air filters can be upgraded to grade M6 and F8, respectively for improved indoor air quality by removing finer particles, pollen, bacteria and dusts. These optional filters are disposable type (non-washable).

Mitsubishi Electric Ventilator Selection Tool

Mitsubishi Electric Ventilator Selection Tool

The Mitsubishi Electric Ventilator Selection Tool allows installers to prepare energy savings calculations comparing a conventional ventilation system to a Lossnay unit. The calculations include annual power consumption (kWH), CO2 emissions (kg) and energy savings ($) for a specific location. The tool also generates Technical Data, including acoustic information.

PZ-62DR-EA/EB wired 7 day controller (Optional)

PZ-62DR-EA/EB wired 7 day controller (Optional)

Backlit LCD Lossnay remote controller provides ON/OFF control, fan speed adjustment, weekly timer, as well as advanced functions such as night-purge, by-pass ventilation and CO2 level display.

Night Purge (Requires PZ-62DR-EA/EB controller)

Night Purge (Requires PZ-62DR-EA/EB controller)

During the summer season, the Night Purge mode draws cooler outside air into the room at night. This energy conservation mode reduces the load when the air conditioning is started up the next morning. With new models, it is possible to manually engage and set the night purge operation.

Bypass Ventilation Mode_LGH

Bypass Ventilation Mode

When the outdoor temperature is close to the indoor temperature, the Lossnay unit can be set to run in by-pass ventilation mode to open the built-in damper inside the unit to exhaust the stale room air straight to outside without going through the heat exchanger.

CO2 sensor (Optional)_LGH

CO2 sensor (Optional)

Mitsubishi Electric can provide option CO2 sensor that can be connected directly to a LOSSNAY RVX3 unit to automatically adjust the fan speed according to the indoor CO2 level. This contributes to further energy savings.
Two types of CO2 sensors are available: wall-mounted (PZ-70CSW-E) and duct-mounted (PZ-70CSD-E) types.

Dual Barrier Coating_LGH

Dual Barrier Coating

Dual Barrier Coating reduces dust and greasy dirt from collecting on the surfaces of the Air Supply Exhaust fan and airborne contaminants sticking to the unit, providing a ventilator that is not only cleaner but also requires less cleaning.

DOWNLOADS

Model:

Specifications

PZ-RFP3-E

PZ-RFP3-E ePM1 75% filter.

Download

Specifications

PZ-RFH3-E

PZ-RFH3-E F8 filter.

Download

Specifications

PZ-RFM3-E

PZ-RFM3-E M6 filter.

Download

Specifications

PZ-RF3-E

PZ-RF3-E standard G4 filter.

Download

Installation Manual

PZ-70CSW-E

PZ-70CSW-E CO2 Sensor installation and instruction manual.

Download

Specifications

PZ-70CSW-E

PZ-70CSW-E CO2 Sensor specifications

Download

Specifications

PZ-70CSD-E

PZ-70CSD-E CO2 Specifications

Download

Installation Manual

PZ-70CSD-E

PZ-70CSD-E CO2 sensor installation and user manual.

Download

REQUEST A QUOTE