Lossnay Ventilation

LGH-RVX-E Lossnay Ventilators

LGH-15-200RVX-E

The Lossnay Fresh Air Energy Recovery Systems set a new standard in ventilation by recovering heat from the air inside your office and transferring it to fresh, dry air introduced from outside. Not only providing energy recovery savings in summer by cooling the warmer fresh air to an acceptable level but also providing excellent energy efficiency in winter. Lossnay heat exchangers have a high efficiency thereby eliminating the need for additional electric elements.

Available in: 15, 25, 35, 50, 65, 80, 100, 150, 200

Simultaneous air supply and exhaust

Simultaneous air supply and exhaust

Lossnay is the ultimate home ventilation system that provides fresh clean air from outside, while removing both moisture and stale indoor air at the same time. Bringing in fresh air into the house can help improve air quality by lowering the amount of CO2.

Heat recovery ventilation_v2

Heat recovery ventilation

Heat is recovered from the outgoing stale air. This heat is utilised to pre-heat incoming fresh air so your heating system is not required to work as hard to maintain desired room temperature.

Use with Mr Slim & City Multi Systems

Use with Mr Slim & City Multi Systems

Lossnay can be integrated with a Mitsubishi Electric Mr. Slim and City Multi air conditioning systems. The ducted system provides heating and cooling while the Lossnay ventilator brings in fresh air into the home while expelling the stale air at the same time.

The heat recovery ventilators to help to reduce the load on the ducted air conditioning system.

Filter (Supplied)

Filter (Supplied)

Filter cuts pollen and dust for fresh clean air. Replacement part no. P-220F-E. (G3 grade Classification :EN779:2012)

High Efficiency Supply Air filter (Optional)_v2

High Efficiency Supply Air filter (Optional)

The supply filter can be upgraded to the high efficency option, a non-washable high efficiency filter (M6 grade Classification :EN779:2012)

PZ-61DR-E wired 7 day controller (Optional)

PZ-61DR-E wired 7 day controller (Optional)

Backlit LCD Lossnay remote controller allows you to program up to 8 separate Start/Stop patterns per day over a 7-day period. Controls 1 to 15 LGH~RVX-E Lossnay units. This controller is not required if a P-Series unit is installed with a wired controller (i.e.. PAR-32).

Night Purge (Requires PZ-61DR-E controller)

Night Purge (Requires PZ-61DR-E controller)

During the summer season, the Night Purge mode draws cooler outside air into the room at night. This energy conservation mode reduces the load when the air conditioning is started up the next morning. With new models, it is possible to manually engage and set the night purge operation.

Lossnay Ventilation Mode

Lossnay Ventilation Mode

Room air is discharged to outside via Lossnay core. Heat exchanged outside air is supplied to the room. In summer and winter, air conditioning energy can be recovered by Lossnay unit.

Bypass Ventilation Mode

Bypass Ventilation Mode

Stale room air is discharged to outside without passing through the Lossnay core. In spring and autumn when air conditioning is not necessary, the unit operates in bypass ventilation mode.

Other Features

  • Air volume 42 l/s (model 15) to 556 l/s (model 200)
  • Clean, fresh air
  • Energy efficient heat recovery
  • Simultaneous air supply and exhaust stale air
  • Heat recovery ventilation
  • Use with Mr Slim and City Multi systems
  • Fresh air without windows open
  • Retains heat
  • Washable supply air filter
Model LGH-35RVX-E
Electrical power supply 220-240V/50Hz, 220V/60Hz
Ventilation mode Heat recovery mode Bypass mode
Fan speed SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1
Running current (A) 0.98 0.54 0.26 0.12 0.98 0.56 0.28 0.13
Input power (W) 140 70 31 11 145 72 35 13
Air volume (m3/h) 350 263 175 88 350 263 175 88
(L/s) 97 73 49 24 97 73 49 24
External static pressure (Pa) 160 90 40 10 160 90 40 10
Temperature exchange efficiency (%) 80.0 82.5 86.0 88.5
Enthalpy exchange efficiency (%) Heating 71.5 74.0 78.5 83.5
Cooling 71.0 73.0 78.0 82.0
Noise (dB) (Measured at 1.5m under the centre of unit in an anechoic chamber) 32.0 28.0 20.0 17.0 32.5 28.0 20.0 18.0
Weight (kg) 30

Model LGH-50RVX-E
Electrical power supply 220-240V/50Hz, 220V/60Hz
Ventilation mode Heat recovery mode Bypass mode
Fan speed SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1
Running current (A) 1.15 0.59 0.26 0.13 1.15 0.59 0.27 0.13
Input power (W) 165 78 32 12 173 81 35 14
Air volume (m3/h) 500 375 250 125 500 375 250 125
(L/s) 139 104 69 35 139 104 69 35
External static pressure (Pa) 120 68 30 8 120 68 30 8
Temperature exchange efficiency (%) 78.0 81.0 83.5 87.0
Enthalpy exchange efficiency (%) Heating 69.0 71.0 75.0 82.5
Cooling 66.5 68.0 72.5 82.0
Noise (dB) (Measured at 1.5m under the centre of unit in an anechoic chamber) 34.0 28.0 19.0 18.0 35.0 29.0 20.0 18.0
Weight (kg) 33
*The Air outlets noise (45  angle,1.5 metres in front of the unit) is about 12dB(LGH-35RVX-E) / 18dB(LGH-50RVX-E) greater than the indicated value (at Fan speed 4).
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
*Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method.

Model LGH-65RVX-E
Electrical power supply 220-240V/50Hz, 220V/60Hz
Ventilation mode Heat recovery mode Bypass mode
Fan speed SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1
Running current (A) 1.65 0.90 0.39 0.15 1.72 0.86 0.38 0.16
Input power (W) 252 131 49 15 262 131 47 17
Air volume (m3/h) 650 488 325 163 650 488 325 163
(L/s) 181 135 90 45 181 135 90 45
External static pressure (Pa) 120 68 30 8 120 68 30 8
Temperature exchange efficiency (%) 77.0 81.0 84.0 86.0
Enthalpy exchange efficiency (%) Heating 68.5 71.0 76.0 82.0
Cooling 66.0 69.5 74.0 81.0
Noise (dB) (Measured at 1.5m under the centre
of unit in an anechoic chamber)
34.5 29.0 22.0 18.0 35.5 29.0 22.0 18.0
Weight (kg) 38
*The Air outlets noise (45  angle,1.5 metres in front of the unit) is about 16dB(LGH-65RVX-E) / 24dB(LGH-80RVX-E) greater than the indicated value (at Fan speed 4).
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
*Use this unit with static pressure 240Pa or less at Fan speed 4. Otherwise the noise level might be large. (Only LGH-80RVX-E)
*Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method.

Model LGH-80RVX-E
Electrical power supply 220-240V/50Hz, 220V/60Hz
Ventilation mode Heat recovery mode Bypass mode
Fan speed SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1
Running current (A) 1.82 0.83 0.36 0.15 1.97 0.86 0.40 0.15
Input power (W) 335 151 60 18 340 151 64 20
Air volume (m3/h) 800 600 400 200 800 600 400 200
(L/s) 222 167 111 56 222 167 111 56
External static pressure (Pa) 150 85 38 10 150 85 38 10
Temperature exchange efficiency (%) 79.0 82.5 84.0 85.0
Enthalpy exchange efficiency (%) Heating 71.0 73.5 78.0 81.0
Cooling 70.0 72.5 78.0 81.0
Noise (dB) (Measured at 1.5m under the centre
of unit in an anechoic chamber)
34.5 30.0 23.0 18.0 36.0 30.0 23.0 18.0
Weight (kg) 48
*The Air outlets noise (45  angle,1.5 metres in front of the unit) is about 16dB(LGH-65RVX-E) / 24dB(LGH-80RVX-E) greater than the indicated value (at Fan speed 4).
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
*Use this unit with static pressure 240Pa or less at Fan speed 4. Otherwise the noise level might be large. (Only LGH-80RVX-E)
*Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method.

Model LGH-100RVX-E
Electrical power supply 220-240V/50Hz, 220V/60Hz
Ventilation mode Heat recovery mode Bypass mode
Fan speed SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1
Running current (A) 2.50 1.20 0.50 0.17 2.50 1.20 0.51 0.19
Input power (W) 420 200 75 21 420 200 75 23
Air volume (m3/h) 1000 750 500 250 1000 750 500 250
(L/s) 278 208 139 69 278 208 139 69
External static pressure (Pa) 170 96 43 11 170 96 43 11
Temperature exchange efficiency (%) 80.0 83.0 86.5 89.5
Enthalpy exchange efficiency (%) Heating 72.5 74.0 78.0 87.0
Cooling 71.0 73.0 77.0 85.5
Noise (dB) (Measured at 1.5m under the centre of unit in an anechoic chamber) 37.0 31.0 23.0 18.0 38.0 32.0 24.0 18.0
Weight (kg) 54
*The Air outlets noise (45  angle,1.5 metres in front of the unit) is about 21dB(LGH-100RVX-E) / 22dB(LGH-150RVX-E) greater than the indicated value (at Fan speed 4).
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
*Use this unit between static pressure 60Pa and 240Pa at Fan speed 4. Otherwise the motor protection may work and reduce its output or the noise level might be larger. (Only LGH-100RVX-E)
*Use this unit with static pressure 250Pa or less at Fan speed 4. Otherwise the noise level might be larger (Only LGH-150RVX-E)
*Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method.

Model LGH-150RVX-E
Electrical power supply 220-240V/50Hz, 220V/60Hz
Ventilation mode Heat recovery mode Bypass mode
Fan speed SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1
Running current (A) 3.71 1.75 0.70 0.29 3.85 1.78 0.78 0.30
Input power (W) 670 311 123 38 698 311 124 44
Air volume (m3/h) 1500 1125 750 375 1500 1125 750 375
(L/s) 417 313 208 104 417 313 208 104
External static pressure (Pa) 175 98 44 11 175 98 44 11
Temperature exchange efficiency (%) 80.0 82.5 84.0 85.0
Enthalpy exchange efficiency (%) Heating 72.0 73.5 78.0 81.0
Cooling 70.5 72.5 78.0 81.0
Noise (dB) (Measured at 1.5m under the centre of unit in an anechoic chamber) 39.0 32.0 24.0 18.0 40.5 33.0 26.0 18.0
Weight (kg) 98
*The Air outlets noise (45  angle,1.5 metres in front of the unit) is about 21dB(LGH-100RVX-E) / 22dB(LGH-150RVX-E) greater than the indicated value (at Fan speed 4).
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
*Use this unit between static pressure 60Pa and 240Pa at Fan speed 4. Otherwise the motor protection may work and reduce its output or the noise level might be larger. (Only LGH-100RVX-E)
*Use this unit with static pressure 250Pa or less at Fan speed 4. Otherwise the noise level might be larger (Only LGH-150RVX-E)
*Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method.