Lossnay Ventilation
LGH-15-200RVX-E
The Lossnay Fresh Air Energy Recovery Systems set a new standard in ventilation by recovering heat from the air inside your office and transferring it to fresh, dry air introduced from outside. Not only providing energy recovery savings in summer by cooling the warmer fresh air to an acceptable level but also providing excellent energy efficiency in winter. Lossnay heat exchangers have a high efficiency thereby eliminating the need for additional electric elements.
Available in: 15, 25, 35, 50, 65, 80, 100, 150, 200
Lossnay is the ultimate home ventilation system that provides fresh clean air from outside, while removing both moisture and stale indoor air at the same time. Bringing in fresh air into the house can help improve air quality by lowering the amount of CO2.
Heat is recovered from the outgoing stale air. This heat is utilised to pre-heat incoming fresh air so your heating system is not required to work as hard to maintain desired room temperature.
Lossnay can be integrated and interlocked with a Mitsubishi Electric Mr. Slim and City Multi air conditioning systems. The ducted system provides heating and cooling while the Lossnay ventilator brings in fresh air into the home while expelling the stale air at the same time.
The heat recovery operation can help reduce the load on the ducted air conditioning system.
Filter cuts pollen and dust for fresh clean air. Replacement part no. P-220F-E. (G3 grade Classification :EN779:2012)
The supply filter can be upgraded to the high efficency option, a non-washable high efficiency filter (M6 grade Classification :EN779:2012)
Backlit LCD Lossnay remote controller allows you to program up to 8 separate Start/Stop patterns per day over a 7-day period. Controls 1 to 15 LGH~RVX-E Lossnay units. This controller is not required if a P-Series unit is installed with a wired controller (i.e.. PAR-32).
During the summer season, the Night Purge mode draws cooler outside air into the room at night. This energy conservation mode reduces the load when the air conditioning is started up the next morning. With new models, it is possible to manually engage and set the night purge operation.
Room air is discharged to outside via Lossnay core. Heat exchanged outside air is supplied to the room. In summer and winter, air conditioning energy can be recovered by Lossnay unit.
Stale room air is discharged to outside without passing through the Lossnay core. In spring and autumn when air conditioning is not necessary, the unit operates in bypass ventilation mode.
Model | LGH-35RVX-E | |||||||||||||||||||||||||||||||
Electrical power supply | 220-240V/50Hz, 220V/60Hz | |||||||||||||||||||||||||||||||
Ventilation mode | Heat recovery mode | Bypass mode | ||||||||||||||||||||||||||||||
Fan speed | SP4 | SP3 | SP2 | SP1 | SP4 | SP3 | SP2 | SP1 | ||||||||||||||||||||||||
Running current (A) | 0.98 | 0.54 | 0.26 | 0.12 | 0.98 | 0.56 | 0.28 | 0.13 | ||||||||||||||||||||||||
Input power (W) | 140 | 70 | 31 | 11 | 145 | 72 | 35 | 13 | ||||||||||||||||||||||||
Air volume | (m3/h) | 350 | 263 | 175 | 88 | 350 | 263 | 175 | 88 | |||||||||||||||||||||||
(L/s) | 97 | 73 | 49 | 24 | 97 | 73 | 49 | 24 | ||||||||||||||||||||||||
External static pressure (Pa) | 160 | 90 | 40 | 10 | 160 | 90 | 40 | 10 | ||||||||||||||||||||||||
Temperature exchange efficiency (%) | 80.0 | 82.5 | 86.0 | 88.5 | – | – | – | – | ||||||||||||||||||||||||
Enthalpy exchange efficiency (%) | Heating | 71.5 | 74.0 | 78.5 | 83.5 | – | – | – | – | |||||||||||||||||||||||
Cooling | 71.0 | 73.0 | 78.0 | 82.0 | – | – | – | – | ||||||||||||||||||||||||
Noise (dB) | (Measured at 1.5m under the centre of unit in an anechoic chamber) | 32.0 | 28.0 | 20.0 | 17.0 | 32.5 | 28.0 | 20.0 | 18.0 | |||||||||||||||||||||||
Weight (kg) | 30 |
Model | LGH-50RVX-E | |||||||||||||||||||||||||||||||
Electrical power supply | 220-240V/50Hz, 220V/60Hz | |||||||||||||||||||||||||||||||
Ventilation mode | Heat recovery mode | Bypass mode | ||||||||||||||||||||||||||||||
Fan speed | SP4 | SP3 | SP2 | SP1 | SP4 | SP3 | SP2 | SP1 | ||||||||||||||||||||||||
Running current (A) | 1.15 | 0.59 | 0.26 | 0.13 | 1.15 | 0.59 | 0.27 | 0.13 | ||||||||||||||||||||||||
Input power (W) | 165 | 78 | 32 | 12 | 173 | 81 | 35 | 14 | ||||||||||||||||||||||||
Air volume | (m3/h) | 500 | 375 | 250 | 125 | 500 | 375 | 250 | 125 | |||||||||||||||||||||||
(L/s) | 139 | 104 | 69 | 35 | 139 | 104 | 69 | 35 | ||||||||||||||||||||||||
External static pressure (Pa) | 120 | 68 | 30 | 8 | 120 | 68 | 30 | 8 | ||||||||||||||||||||||||
Temperature exchange efficiency (%) | 78.0 | 81.0 | 83.5 | 87.0 | – | – | – | – | ||||||||||||||||||||||||
Enthalpy exchange efficiency (%) | Heating | 69.0 | 71.0 | 75.0 | 82.5 | – | – | – | – | |||||||||||||||||||||||
Cooling | 66.5 | 68.0 | 72.5 | 82.0 | – | – | – | – | ||||||||||||||||||||||||
Noise (dB) | (Measured at 1.5m under the centre of unit in an anechoic chamber) | 34.0 | 28.0 | 19.0 | 18.0 | 35.0 | 29.0 | 20.0 | 18.0 | |||||||||||||||||||||||
Weight (kg) | 33 | |||||||||||||||||||||||||||||||
*The Air outlets noise (45 angle,1.5 metres in front of the unit) is about 12dB(LGH-35RVX-E) / 18dB(LGH-50RVX-E) greater than the indicated value (at Fan speed 4). *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz. *For the specification at the other frequency contact your dealer. *Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method. |
Model | LGH-65RVX-E | ||||||||||||||||||||||||||
Electrical power supply | 220-240V/50Hz, 220V/60Hz | ||||||||||||||||||||||||||
Ventilation mode | Heat recovery mode | Bypass mode | |||||||||||||||||||||||||
Fan speed | SP4 | SP3 | SP2 | SP1 | SP4 | SP3 | SP2 | SP1 | |||||||||||||||||||
Running current (A) | 1.65 | 0.90 | 0.39 | 0.15 | 1.72 | 0.86 | 0.38 | 0.16 | |||||||||||||||||||
Input power (W) | 252 | 131 | 49 | 15 | 262 | 131 | 47 | 17 | |||||||||||||||||||
Air volume | (m3/h) | 650 | 488 | 325 | 163 | 650 | 488 | 325 | 163 | ||||||||||||||||||
(L/s) | 181 | 135 | 90 | 45 | 181 | 135 | 90 | 45 | |||||||||||||||||||
External static pressure (Pa) | 120 | 68 | 30 | 8 | 120 | 68 | 30 | 8 | |||||||||||||||||||
Temperature exchange efficiency (%) | 77.0 | 81.0 | 84.0 | 86.0 | – | – | – | – | |||||||||||||||||||
Enthalpy exchange efficiency (%) | Heating | 68.5 | 71.0 | 76.0 | 82.0 | – | – | – | – | ||||||||||||||||||
Cooling | 66.0 | 69.5 | 74.0 | 81.0 | – | – | – | – | |||||||||||||||||||
Noise (dB) | (Measured at 1.5m under the centre of unit in an anechoic chamber) |
34.5 | 29.0 | 22.0 | 18.0 | 35.5 | 29.0 | 22.0 | 18.0 | ||||||||||||||||||
Weight (kg) | 38 | ||||||||||||||||||||||||||
*The Air outlets noise (45 angle,1.5 metres in front of the unit) is about 16dB(LGH-65RVX-E) / 24dB(LGH-80RVX-E) greater than the indicated value (at Fan speed 4). *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz. *For the specification at the other frequency contact your dealer. *Use this unit with static pressure 240Pa or less at Fan speed 4. Otherwise the noise level might be large. (Only LGH-80RVX-E) *Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method. |
Model | LGH-80RVX-E | ||||||||||||||||||||||||||||
Electrical power supply | 220-240V/50Hz, 220V/60Hz | ||||||||||||||||||||||||||||
Ventilation mode | Heat recovery mode | Bypass mode | |||||||||||||||||||||||||||
Fan speed | SP4 | SP3 | SP2 | SP1 | SP4 | SP3 | SP2 | SP1 | |||||||||||||||||||||
Running current (A) | 1.82 | 0.83 | 0.36 | 0.15 | 1.97 | 0.86 | 0.40 | 0.15 | |||||||||||||||||||||
Input power (W) | 335 | 151 | 60 | 18 | 340 | 151 | 64 | 20 | |||||||||||||||||||||
Air volume | (m3/h) | 800 | 600 | 400 | 200 | 800 | 600 | 400 | 200 | ||||||||||||||||||||
(L/s) | 222 | 167 | 111 | 56 | 222 | 167 | 111 | 56 | |||||||||||||||||||||
External static pressure (Pa) | 150 | 85 | 38 | 10 | 150 | 85 | 38 | 10 | |||||||||||||||||||||
Temperature exchange efficiency (%) | 79.0 | 82.5 | 84.0 | 85.0 | – | – | – | – | |||||||||||||||||||||
Enthalpy exchange efficiency (%) | Heating | 71.0 | 73.5 | 78.0 | 81.0 | – | – | – | – | ||||||||||||||||||||
Cooling | 70.0 | 72.5 | 78.0 | 81.0 | – | – | – | – | |||||||||||||||||||||
Noise (dB) | (Measured at 1.5m under the centre of unit in an anechoic chamber) |
34.5 | 30.0 | 23.0 | 18.0 | 36.0 | 30.0 | 23.0 | 18.0 | ||||||||||||||||||||
Weight (kg) | 48 | ||||||||||||||||||||||||||||
*The Air outlets noise (45 angle,1.5 metres in front of the unit) is about 16dB(LGH-65RVX-E) / 24dB(LGH-80RVX-E) greater than the indicated value (at Fan speed 4). *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz. *For the specification at the other frequency contact your dealer. *Use this unit with static pressure 240Pa or less at Fan speed 4. Otherwise the noise level might be large. (Only LGH-80RVX-E) *Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method. |
Model | LGH-100RVX-E | ||||||||||||||||||||||||||
Electrical power supply | 220-240V/50Hz, 220V/60Hz | ||||||||||||||||||||||||||
Ventilation mode | Heat recovery mode | Bypass mode | |||||||||||||||||||||||||
Fan speed | SP4 | SP3 | SP2 | SP1 | SP4 | SP3 | SP2 | SP1 | |||||||||||||||||||
Running current (A) | 2.50 | 1.20 | 0.50 | 0.17 | 2.50 | 1.20 | 0.51 | 0.19 | |||||||||||||||||||
Input power (W) | 420 | 200 | 75 | 21 | 420 | 200 | 75 | 23 | |||||||||||||||||||
Air volume | (m3/h) | 1000 | 750 | 500 | 250 | 1000 | 750 | 500 | 250 | ||||||||||||||||||
(L/s) | 278 | 208 | 139 | 69 | 278 | 208 | 139 | 69 | |||||||||||||||||||
External static pressure (Pa) | 170 | 96 | 43 | 11 | 170 | 96 | 43 | 11 | |||||||||||||||||||
Temperature exchange efficiency (%) | 80.0 | 83.0 | 86.5 | 89.5 | – | – | – | – | |||||||||||||||||||
Enthalpy exchange efficiency (%) | Heating | 72.5 | 74.0 | 78.0 | 87.0 | – | – | – | – | ||||||||||||||||||
Cooling | 71.0 | 73.0 | 77.0 | 85.5 | – | – | – | – | |||||||||||||||||||
Noise (dB) | (Measured at 1.5m under the centre of unit in an anechoic chamber) | 37.0 | 31.0 | 23.0 | 18.0 | 38.0 | 32.0 | 24.0 | 18.0 | ||||||||||||||||||
Weight (kg) | 54 | ||||||||||||||||||||||||||
*The Air outlets noise (45 angle,1.5 metres in front of the unit) is about 21dB(LGH-100RVX-E) / 22dB(LGH-150RVX-E) greater than the indicated value (at Fan speed 4). *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz. *For the specification at the other frequency contact your dealer. *Use this unit between static pressure 60Pa and 240Pa at Fan speed 4. Otherwise the motor protection may work and reduce its output or the noise level might be larger. (Only LGH-100RVX-E) *Use this unit with static pressure 250Pa or less at Fan speed 4. Otherwise the noise level might be larger (Only LGH-150RVX-E) *Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method. |
Model | LGH-150RVX-E | ||||||||||||||||||||||||||||||
Electrical power supply | 220-240V/50Hz, 220V/60Hz | ||||||||||||||||||||||||||||||
Ventilation mode | Heat recovery mode | Bypass mode | |||||||||||||||||||||||||||||
Fan speed | SP4 | SP3 | SP2 | SP1 | SP4 | SP3 | SP2 | SP1 | |||||||||||||||||||||||
Running current (A) | 3.71 | 1.75 | 0.70 | 0.29 | 3.85 | 1.78 | 0.78 | 0.30 | |||||||||||||||||||||||
Input power (W) | 670 | 311 | 123 | 38 | 698 | 311 | 124 | 44 | |||||||||||||||||||||||
Air volume | (m3/h) | 1500 | 1125 | 750 | 375 | 1500 | 1125 | 750 | 375 | ||||||||||||||||||||||
(L/s) | 417 | 313 | 208 | 104 | 417 | 313 | 208 | 104 | |||||||||||||||||||||||
External static pressure (Pa) | 175 | 98 | 44 | 11 | 175 | 98 | 44 | 11 | |||||||||||||||||||||||
Temperature exchange efficiency (%) | 80.0 | 82.5 | 84.0 | 85.0 | – | – | – | – | |||||||||||||||||||||||
Enthalpy exchange efficiency (%) | Heating | 72.0 | 73.5 | 78.0 | 81.0 | – | – | – | – | ||||||||||||||||||||||
Cooling | 70.5 | 72.5 | 78.0 | 81.0 | – | – | – | – | |||||||||||||||||||||||
Noise (dB) | (Measured at 1.5m under the centre of unit in an anechoic chamber) | 39.0 | 32.0 | 24.0 | 18.0 | 40.5 | 33.0 | 26.0 | 18.0 | ||||||||||||||||||||||
Weight (kg) | 98 | ||||||||||||||||||||||||||||||
*The Air outlets noise (45 angle,1.5 metres in front of the unit) is about 21dB(LGH-100RVX-E) / 22dB(LGH-150RVX-E) greater than the indicated value (at Fan speed 4). *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz. *For the specification at the other frequency contact your dealer. *Use this unit between static pressure 60Pa and 240Pa at Fan speed 4. Otherwise the motor protection may work and reduce its output or the noise level might be larger. (Only LGH-100RVX-E) *Use this unit with static pressure 250Pa or less at Fan speed 4. Otherwise the noise level might be larger (Only LGH-150RVX-E) *Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method. |
Brochure
Learn more about Lossnay Fresh Air Energy Recovery Systems.