North Lakes Medical Centre

Heat recovery CITY MULTI VRF system utilising M-NET for individual tenancy controlled heating and cooling and indoor unit power isolation for staged tenancy fit out.

Download PDF
North Lakes Medical Centre is served by City Multi high static ducted vrf units.

The challenge

North Lakes Specialist Medical Centre, located in one of the fastest growing master planned communities in South East Queensland. The modern architecturally designed building features four levels, and is home to a range of specialist and ancillary medical services providing much needed support, with a focus on Preventative Cardiology and Metabolic Disease, to the local community.

The Centre required individually controlled heating and cooling for multiple tenants including state of the art medical suites. Some parts of the building would require heating while other spaces would require cooling at the same time.

The newly constructed building would require staged fit out as new tenants move in. Air conditioning indoor units located in unoccupied spaces would need to be unpowered until required.

Overhead view of the Mitsubishi Electric CITY MULTI outdoor units arranged in rows across the North Lakes Medical Centre roof

The solution

Mitsubishi Electric City Multi 2-pipe heat recovery technology was selected, providing simultaneous heating and cooling for multiple indoor units connected to a single outdoor unit. The 2-pipe system, unique to Mitsubishi Electric, uses a central branch controller and delivers substantial installation savings over conventional 3-pipe heat recovery systems due to the reduced amount of copper refrigerant piping required, particularly on a larger site.

Independent temperature control per tenancy is provided by M-NET, the integrated communications control transmission network unique to Mitsubishi Electric. Power to the indoor units in unoccupied tenancies was isolated also via M-NET, while other indoor units continued to operate.

This enables a staged tenancy fit out and ongoing refurbishments to occur without effecting neighbouring tenancies connected to the same outdoor unit.

Unit Information

Heat Recovery

Air Cooled Heat Recovery

  • Capacity range: 22 to 124 kW
  • 2-pipe heat recovery for simultaneous heating and cooling
  • Reduced condenser footprint
  • External static pressure up to 80 Pa
  • Max. height difference up to 90 m
  • Cooling operation up to 52°C ambient
Read more

Heat Pump

PUMY-P Series

  • Capacity Range: 12.5 - 33.5 kW
  • Extended Pipe Runs
  • Broad compatibility – over 100 indoor units to choose from
  • Outdoor Unit Fan Design
  • Inverter Control
  • Wide Operating Range
Read more

Heat Pump

Air Cooled Heat Pump

  • Capacity range: 22 to 150 kW
  • Reduced condenser footprint
  • External static pressure up to 80 Pa
  • Max. height difference up to 90 m
  • Advanced “Low Noise” function
Read more

Ceiling Concealed

PEFY-P-VMHS-E

  • Capacity Range: 4.5 – 16 kW
  • Flexible duct design
  • Drain pump (option)
  • DC fan motor
  • External Static Pressure 50-250 Pa
  • Three fan speeds settings
Read more

City Multi VRF Air Conditioning Systems

City Multi - BC Controller

  • 2-pipe heat recovery for simultaneous heating and cooling
  • Single BC controller for systems up to 40 kW
  • Main BC controller for 40, 101 or 124 kW outdoor units
  • Connects up to 11 sub-BC controllers
  • Up to 90 m piping from BC controller to indoor units
  • Line branching reduces refrigerant use
Read more